The HSC LCX-3 is an alloy-steel cantilever (shear) beam load cell: one end is fixed and the other takes the load through a cylindrical indenter. It is well sealed (IP67), adjusts itself under force, is easy to install and interchangeable, and comes in 500 kg, 1 t, 2 t and 3 t. It is used to build ultra-thin truck scales, monorail crane scales and hopper scales.
Why scale makers choose it
- Accurate: ±0.02% FS total error, 2.0 mV/V.
- Well sealed: IP67, alloy steel.
- Strong overload margin: safe 150%, limit 300% of full scale.
- Easy to fit and interchangeable.
- 500 kg to 3 t capacities.
Specifications
| Model | HSC LCX-3 |
|---|---|
| Type | Cantilever (shear) beam, loaded through a cylindrical indenter |
| Capacities | 500, 1,000, 2,000, 3,000 kg |
| Sensitivity | 2.0 ± 0.004 mV/V |
| Total error | ±0.02% FS (±0.05% FS max) |
| Creep (30 min) | 0.02% FS |
| Zero balance | ±1% FS |
| Temperature effect | Zero ±0.02% FS / 10 °C; span ±0.02% FS / 10 °C |
| Temperature range | Compensated −10 to +40 °C; operating −30 to +60 °C |
| Overload | Safe 150% FS; limit 300% FS |
| Excitation | 5 – 15 V DC recommended; 20 V DC max |
| Impedance | Input 381 ± 4 Ω; output 350 ± 1 Ω |
| Protection | IP67 |
| Material | Alloy steel |
| Cable | 4 m, Ø 5.2 mm |
| Wiring | Input + red, input − black, output + green, output − white, shield yellow |
| Warranty | 1 year |
Which load cell?
From 50 kg, see the LCX-1 (50 kg – 3 t); for a low installation height, the LCX-2-S; for heavier weighbridge loads, the LCZ-4 column cell (20 – 60 t). Browse all load cells.
Where it is used
Ultra-thin truck scales, monorail crane scales and hopper scales.
Questions buyers ask
500 kg, 1 t, 2 t and 3 t.
To IP67.
Input + red, input − black, output + green, output − white, and a yellow shield; 4 m cable.
Order or ask for a quotation
Tell us the capacity and quantity. Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.