The HSCo HSC-I-MCC mould cultivation cabinet grows mould cultures under controlled temperature and humidity, for microbiology labs, research centres, pharmaceutical QC and food testing. It works from 0 to 65 °C (10 to 65 °C with humidification) and 45 to 95% RH, with forced air, a compressor for cooling, automatic defrost and a 30-segment programmable controller with a PT100 sensor. The mirror stainless-steel chamber has an ozone-free sterilising lamp, an over-temperature alarm and power-failure memory. It comes in 70, 150 and 250 litres.
Why labs choose it
- Temperature and humidity control: 0 – 65 °C; 45 – 95% RH, ±5% RH.
- Heats and cools: air-cooled compressor with R134a, automatic defrost.
- 30-segment programs on an LCD controller, timer up to 99.9 h per segment.
- Even conditions: forced air, ±1 °C uniformity.
- Clean and safe: ozone-free sterilising lamp, over-temperature alarm, self-diagnosis.
- Three sizes: 70, 150 and 250 litres.
Specifications
| Model | HSC-I-MCC-70BL | HSC-I-MCC-150BL | HSC-I-MCC-250BL |
|---|---|---|---|
| Volume | 70 L | 150 L | 250 L |
| Inner chamber (W × L × H) | 415 × 350 × 500 mm | 490 × 400 × 750 mm | 500 × 515 × 950 mm |
| Outside size (W × L × H) | 571 × 591 × 1,051 mm | 646 × 641 × 1,301 mm | 656 × 741 × 1,501 mm |
| Packed size (W × L × H) | 680 × 676 × 1,235 mm | 751 × 730 × 1,490 mm | 761 × 830 × 1,690 mm |
| Power rating | 1.8 kW | 2.0 kW | 2.2 kW |
| Supply | 220 V AC, 8.2 A | 220 V AC, 9.1 A | 220 V AC, 10 A |
| Maximum shelves | 5 | 9 | 12 |
| Net / gross weight | 69 / 92 kg | 86 / 114 kg | 100 / 139 kg |
| Air flow | Forced convection |
|---|---|
| Temperature range | 0 – 65 °C without humidification; 10 – 65 °C with humidification |
| Resolution / fluctuation / uniformity | 0.1 °C / ±0.5 °C (high temperature), ±1 °C (low temperature) / ±1 °C |
| Humidity | 45 – 95% RH, ±5% RH; automatic control; external humidifier; anti-condensation sensor |
| Refrigeration | Air-cooled hermetic compressor, R134a; intelligent automatic defrost |
| Controller | 30-segment LCD program controller; touch buttons; timer 0 – 99.9 h per segment; PT100 sensor |
| Modes | Fixed value, timer, auto stop, program |
| Other functions | Deviation correction, key lock, power-failure memory, UV lamp, loop self-diagnosis |
| Sterilising lamp | Standard, ozone-free |
| Safety | Over-temperature alarm |
| Chamber / shell / insulation | Mirror stainless steel / cold-rolled steel, powder coated / polyurethane |
| Heater | Stainless-steel heater |
| Test hole / socket | Ø 43 mm plastic test hole; one controlled universal socket |
| Shelves | 2 shelves and 4 shelf racks supplied; 15 kg per shelf; 35 mm spacing |
| Options | Spare shelves, touch-screen controller, RS-485, USB interface and software, printer, recorder, remote control, U-disk storage |
| Warranty | 1 year |
Which incubator?
For cooling below room temperature without humidity, see the cooling / BOD incubator. Browse all ovens and furnaces.
Where it is used
Microbiology research, pharmaceutical quality control and food testing laboratories: growing mould cultures under controlled conditions.
Questions buyers ask
0 – 65 °C (10 – 65 °C when humidifying) and 45 – 95% relative humidity.
Yes. The LCD controller runs up to 30 segments, each up to 99.9 hours.
70, 150 and 250 litres.
Order or ask for a quotation
Tell us the size you need. Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.