The HSCo HSC-FH laboratory fume hood keeps hazardous fumes, vapours and dust away from the user in chemical, pharmaceutical and research labs. Air is drawn in through the front at 0.4 to 0.6 m/s and changed at least 12 to 15 times an hour, then sent out through ducting or, on ductless models, cleaned through HEPA and carbon filters. A vertical sliding safety-glass sash sets the working opening, and a digital panel shows the airflow and controls the fan and lights. Alarms warn of low airflow, a saturated filter or an open sash. The standard size is 1,200 × 750 × 2,300 mm, with other sizes on request.
Why labs choose the HSC-FH
- Safe working: 0.4 – 0.6 m/s face velocity, adjustable.
- Ducted or ductless (HEPA / carbon filters).
- Airflow monitor and alarms for low airflow, filter saturation and open sash.
- Chemical-resistant: epoxy-coated interior; epoxy, phenolic or stainless-steel work surface.
- Quiet: 60 dB or less.
Specifications
| Type | Ducted or ductless (by model) |
|---|---|
| Construction | Powder-coated mild steel or stainless steel; interior with chemical-resistant epoxy coating |
| Work surface | Epoxy resin, phenolic resin or stainless steel |
| Sash | Vertical sliding safety glass, counterbalanced |
| Airflow | 0.4 – 0.6 m/s, adjustable; at least 12 – 15 air changes per hour |
| Exhaust | External ducting, or recirculation through HEPA / carbon filters (ductless) |
| Lighting | LED or fluorescent, chemical resistant, 500 – 1,000 lux |
| Controls | Digital display with airflow monitor, fan control and light switch |
| Alarms | Visual and audible: low airflow, filter saturation, sash open |
| Safety | Emergency stop, sash lock, over-current protection |
| Noise | ≤ 60 dB |
| Standard size | 1,200 × 750 × 2,300 mm; other sizes on request |
| Power | AC 220 V ±10%, 50 / 60 Hz |
| Options | Gas taps, water taps, electrical sockets, fire suppression system |
| Warranty | 1 year |
Which cabinet?
For a compact bench-top cabinet with HEPA and UV, see the mini laminar flow cabinet / mini fume hood; for benches, cabinets and sinks to go with it, laboratory furniture. Browse all laboratory furniture.
Where it is used
Safe handling of hazardous chemicals, fumes, vapours and dust in chemical, pharmaceutical and research laboratories.
Questions buyers ask
Both are made. Ducted hoods vent outside; ductless hoods clean the air through HEPA and carbon filters and return it to the room.
The standard size is 1,200 × 750 × 2,300 mm; other sizes are made on request.
Yes. It alarms on low airflow, a saturated filter or an open sash.
Ask for a quotation
Tell us the size, ducted or ductless, and the services (gas, water, sockets) you need. Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.