FTIR Spectrometer HSC-FTIR – 4,000 to 400 cm⁻¹, 0.5 to 4 cm⁻¹ Resolution, ATR and Transmission
Price on Request
FTIR spectrometer HSC-FTIR: 4,000 – 400 cm⁻¹ (7,800 – 350 cm⁻¹ optional), 0.5 – 4 cm⁻¹ resolution, S/N ≥ 40,000:1, Michelson interferometer, DTGS or MCT detector, ATR, liquid, gas and diffuse-reflectance sampling, library-matching software. For chemical, pharma, polymer and environmental labs. 1-year warranty.
The HSCo HSC-FTIR spectrometer identifies organic and inorganic compounds from their infrared spectrum, for chemical, pharmaceutical, polymer and environmental labs. It is used to check what a sample is made of, find impurities and confirm that products are consistent. A stable Michelson interferometer covers 4,000 to 400 cm⁻¹ as standard (7,800 to 350 cm⁻¹ as an option) at 0.5 to 4 cm⁻¹ resolution, with a signal-to-noise ratio of at least 40,000:1. Accessories take solids, liquids and gases, and the software matches spectra against libraries and prints reports.
Why labs choose it
- Wide range: 4,000 – 400 cm⁻¹, extendable to 7,800 – 350 cm⁻¹.
- Sharp spectra: 0.5 – 4 cm⁻¹ resolution, S/N ≥ 40,000:1.
- Solids, liquids and gases: ATR, liquid cells, gas cells, diffuse reflectance.
- Library matching, quantitative and qualitative analysis, automatic baseline correction.
- Compact, vibration-resistant design.
Specifications
| Spectral range | 4,000 – 400 cm⁻¹ (typical); 7,800 – 350 cm⁻¹ optional |
|---|---|
| Resolution | 0.5 – 4 cm⁻¹, selectable |
| Signal-to-noise | ≥ 40,000:1 (peak to peak) |
| Interferometer | Michelson, high stability |
| Detector | DTGS, or MCT (liquid-nitrogen cooled) |
| Source | Mid-IR (Globar or ceramic) |
| Sampling | ATR; transmission cells for liquids; gas cells; diffuse reflectance for solids |
| Scan speed | 0.1 – 32 scans per second |
| Software | Acquisition, processing, library matching; quantitative and qualitative analysis; baseline correction, peak identification |
| Data output | USB, Ethernet or direct PC connection |
| Power | 220 – 240 V, 50 / 60 Hz |
| Warranty | 1 year |
Which instrument?
For UV and visible absorbance, see the double beam UV-Vis spectrophotometer; for fluorescence, the spectrofluorometer HSC-SFM; to separate volatile compounds, the gas chromatograph HSC-HPGC. Browse all laboratory equipment.
Where it is used
Chemical, pharmaceutical, polymer and environmental labs: identifying compounds, detecting impurities and quality control.
Questions buyers ask
Organic and inorganic compounds, from their infrared spectrum, with library matching.
Yes. It takes ATR, liquid transmission cells, gas cells and a diffuse-reflectance accessory for solids.
DTGS, or MCT cooled with liquid nitrogen. Tell us your application and we will advise.
Ask for a quotation
Tell us your samples and the accessories you need. Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.
You may also like…
Atomic Absorption Spectrophotometer HSC-AAS – Flame and Graphite Furnace AAS for Metals
Double Beam UV-Vis Spectrophotometer HSCE-SPM-KLD – 190 to 1,100 nm, Keypad, LCD, USB
Double-beam UV-Vis spectrophotometer HSCE-SPM-KLD series: 190–1,100 nm, keypad with 320 × 240 LCD, photometry, quantitation, spectrum scan, kinetics, multi-wavelength and DNA/protein, 1,024 MB memory, USB export to Excel, socket-type D2 and W lamps, 5–100 mm cuvettes. 1-year warranty.
Gas Chromatograph and GC-MS System HSC-GCMC
Gas Chromatograph HSC-HPGC – FID / TCD / ECD, Oven to 450 °C
HPLC System HSC-HPLC – 0.001 to 10 mL/min, 6,000 psi, UV / PDA Detectors, Gradient
ICP-OES and ICP-MS Systems HSC – Multi-Element Trace Analysis, Sub-ppb to ppt
ICP-OES and ICP-MS systems for multi-element trace analysis: ICP-OES 165 – 800 nm, sub-ppb to ppm, CCD optics; ICP-MS 6 – 250 amu, down to ppt, isotope analysis; automatic calibration and interference correction; autosampler and other options. For environmental, pharma, food and geological labs. 1-year warranty.
Portable Colorimeter HSC-CP – Platinum-Cobalt 20 to 500 PCU, IP54, Rechargeable
TOC Analyzer HSC-TOCA – TC, IC and TOC, NDIR, up to 20,000 mg/L
TOC analyzer HSC-TOCA: measures TC, IC and TOC in water by high-temperature combustion (680 - 1,000 °C) or UV-persulfate oxidation with NDIR detection, up to 20,000 mg/L, detection limit ≤ 5 µg/L on high-sensitivity models, ±2%, automatic KHP calibration, USB / RS-232 / RS-485, LIMS. 1-year warranty.