Gas Chromatograph and GC-MS System HSC-GCMC

Price on Request

★★★★★4.8from 1,363 Google reviews of Hindustan Scale CompanyRead reviews ›

GC or integrated GC-MS: FID, TCD, ECD (FPD or NPD optional), oven ambient +5 °C to 450 °C with 20 ramps, split/splitless injector with EPC, MS 1–1,200 amu with EI source and turbo pump, Windows software with library search. Autosampler and headspace options. 1-year warranty.

Price on Request

Ask for a quotation

Or call +91-7045922250 or use the WhatsApp button.

Description

The HSC-GCMC is a gas chromatograph that can be supplied on its own (GC) or with a mass spectrometer (GC-MS). It separates, identifies and measures volatile and semi-volatile organic compounds. The GC offers FID, TCD and ECD detectors, with FPD or NPD as options. The column oven runs from 5 °C above ambient to 450 °C with up to 20 ramps. Electronic pneumatic control handles helium, nitrogen or hydrogen carrier gas. The mass spectrometer covers 1 – 1,200 amu with an electron impact source and turbomolecular vacuum. It serves environmental, food, pharmaceutical, petrochemical and forensic labs.

Why labs choose it

  • GC or GC-MS. Start with a standalone GC or take the integrated GC-MS system.
  • Choice of detectors. FID, TCD and ECD; FPD or NPD optional.
  • Wide, fast oven. Ambient +5 °C to 450 °C, up to 100 °C/min, ±0.1 °C stability, 20 ramps and 21 plateaus.
  • Sensitive MS. Under 1 pg octafluoronaphthalene at S/N ≥ 10:1; scans up to 12,500 u/s.
  • Complete software. Windows data system with peak identification, library search and quantitation.
  • Grows with you. Autosampler, headspace, purge-and-trap and thermal desorber options.

Specifications

SystemStandalone GC or integrated GC-MS
GC detectorsFID, TCD, ECD; FPD or NPD optional
Column ovenAmbient +5 °C to 450 °C; up to 20 ramps and 21 plateaus; heating up to 100 °C/min; stability ±0.1 °C
InjectorSplit/splitless, programmable up to 400 °C; on-column, PTV or gas sampling valve optional
Carrier gasElectronic pneumatic control (EPC) of flow and pressure; helium, nitrogen or hydrogen
Column flow0.1 – 20 ml/min, depending on column and mode
ColumnsCapillary, packed or micro-bore; leak-free connection system
MS ion sourceElectron impact (EI); chemical ionisation (CI) optional
Mass range / accuracy1 – 1,200 amu / ≤ ±0.1 amu
MS detectorElectron multiplier
Scan speedUp to 12,500 u/s
MS sensitivity< 1 pg octafluoronaphthalene (OFN) at S/N ≥ 10:1
GC-MS interfaceHeated transfer line up to 320 °C
VacuumTurbomolecular pump with rotary backing pump
SoftwareWindows data acquisition and analysis; peak identification, library search (NIST, Wiley), quantitation; real-time chromatogram and spectra
Power220 V ±10%, 50/60 Hz, single phase
Operating conditions15 – 30 °C; up to 80% RH, non-condensing
OptionsAutosampler, headspace sampler, purge-and-trap unit, thermal desorber
Warranty1 year

Which chromatograph?

For a GC with detectors only, see the high-performance gas chromatograph HSC-HPGC. Browse all laboratory equipment.

Where it is used

Environmental analysis, food testing, pharmaceuticals, petrochemicals and forensic laboratories.

Questions buyers ask

A GC separates and measures compounds with a detector such as FID or TCD. GC-MS adds a mass spectrometer that also identifies each compound from its mass spectrum.

Helium, nitrogen or hydrogen, under electronic pneumatic control.

Yes, with the optional autosampler; headspace, purge-and-trap and thermal desorption are also available.

220 V ±10%, 50/60 Hz, single phase, in a room at 15 – 30 °C.

Ask for a quotation

Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com with your samples, the detectors you need and whether you want GC or GC-MS. Hindustan Scale Company, Mumbai, since 1955.