The HSC-H-PSH paddle sterile homogenizer blends samples inside a sealed sterile bag, so nothing touches the machine and samples cannot cross-contaminate. Stainless-steel paddles beat the bag 3 to 12 times a second to mix, emulsify and release microbes from the sample. It is used for food, pharmaceutical, environmental and clinical microbiology testing. It takes 3 – 400 ml in a 17 × 30 cm bag. You program it on a 4.3-inch touch screen, with up to 8 combined program steps. Three models are available: the basic PS4, the PS4M with UV sterilisation, and the PS4GM with UV sterilisation and temperature control up to 60 °C.
Why labs choose it
- No cross-contamination. The sample stays sealed in a sterile bag throughout.
- Adjustable blending. Paddle speed 3 – 12 strokes per second; paddle gap 0 – 50 mm.
- Programmable. Microcomputer control with 8-step combination programs and stored settings.
- Safe to use. Toughened-glass safety door, anti-pinch automatic stop, soft start and pause.
- UV sterilisation (PS4M, PS4GM) and temperature control up to 60 °C (PS4GM).
Models
| Model | HSC-H-PS4 | HSC-H-PS4M | HSC-H-PS4GM |
|---|---|---|---|
| UV sterilisation (253.7 nm) | No | Yes | Yes |
| Temperature control | No | No | Room temperature to 60 °C |
| Power (220 V) | 200 W | 250 W | 500 W |
| Weight | 24 kg | 24.5 kg | 25 kg |
Specifications
| Control | Microcomputer control; 8-section combination programming; parameter storage |
|---|---|
| Display | 4.3-inch capacitive touch screen |
| Blending time | Up to 99 min 59 s, or continuous |
| Paddle speed | 3 – 12 strokes per second |
| Effective volume | 3 – 400 ml |
| Sterile bag size | 17 × 30 cm |
| Paddles | Stainless steel with anti-corrosion coating |
| Paddle gap | 0 – 50 mm, adjustable |
| Start / pause | Soft start; pause function |
| Safety | Anti-pinch automatic stop; removable window; toughened-glass safety door |
| Outer size | 460 × 250 × 330 mm |
| Warranty | 1 year |
Which homogenizer?
For high-speed mechanical homogenizing, see the lab homogenizer HSC-H-LH; for ultrasonic cell disruption, the ultrasonic homogenizer HSC-H-IUH-A. Browse all homogenizers and stirrers.
Where it is used
Microbiology labs in food safety, pharmaceuticals and environmental testing, for pathogen detection, quality control and clinical diagnostics.
Questions buyers ask
The sample goes into a sterile bag, and stainless-steel paddles press the bag rapidly, blending the sample and releasing microbes into the liquid for testing.
3 to 400 ml, in 17 × 30 cm sterile bags.
The PS4 is the basic model; the PS4M adds UV sterilisation; the PS4GM adds UV sterilisation and temperature control up to 60 °C.
It has a toughened-glass safety door and an anti-pinch automatic stop.
Order or ask for a quotation
Choose the model and add it to your cart, or call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.