The HSCo video melting point meter finds the melting point of pharmaceutical and chemical samples by heating them at a set rate and watching them on camera. It tests four samples a batch, magnified 7 times, from room temperature up to 350 – 420 °C depending on the model, with ±0.3 °C accuracy below 250 °C. A TFT touchscreen runs the tests, and results go to USB, RS-232, SD card or Ethernet. Five models, HSC-VM30 to HSC-VM90, range from semi-automatic to fully automatic detection, with video playback, user accounts and method storage on the higher models.
Why labs choose it
- See the melt: camera view at 7× magnification; video playback on most models.
- 4 samples per batch.
- Accurate: ±0.3 °C below 250 °C, ±0.5 °C above; repeatability ±0.1 °C.
- Heating rate 0.1 – 20 °C/min.
- Semi- or fully automatic detection.
- Records: up to 1,000 results, user accounts and stored methods; USB, RS-232, SD card, Ethernet.
Specifications
| Model | HSC-VM30 | HSC-VM50 | HSC-VM70 | HSC-VM80 | HSC-VM90 |
|---|---|---|---|---|---|
| Temperature range | RT – 350 °C | RT – 400 °C | RT – 350 °C | RT – 400 °C | RT – 420 °C |
| Detection | Semi-automatic | Semi-automatic | Fully automatic | Fully automatic | Fully automatic |
| Video playback | No | Yes | No | Yes | Yes |
| Operator accounts | – | 8 | 8 | 10 | 20 |
| Results stored | 200 | 400 | 400 | 600 | 1,000 |
| Methods stored | – | – | – | 40 groups | 100 groups |
| SD card | 8 GB | 8 GB | 8 GB | 16 GB | 32 GB |
| All models | 4 samples per batch; 0.1 °C resolution; heating rate 0.1 – 20 °C/min; 7× magnification |
|---|---|
| Accuracy | ±0.3 °C (below 250 °C); ±0.5 °C (above 250 °C) |
| Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Display | TFT touchscreen |
| Interfaces | USB, RS-232, SD card, Ethernet |
| Power | 110 – 220 V, 50/60 Hz, 120 W |
| Warranty | 1 year |
Which model?
Choose the semi-automatic HSC-VM30 or VM50, or the fully automatic VM70, VM80 or VM90; the VM90 has the widest range (to 420 °C), 20 user accounts and 1,000 stored results. Browse all temperature control equipment.
Where it is used
Pharmaceutical and chemical labs, research labs and academic institutions: melting point determination with a video record.
Questions buyers ask
Four per batch.
The VM70, VM80 and VM90 detect the melting point fully automatically; the VM30 and VM50 are semi-automatic.
Yes, on the VM50, VM80 and VM90, which have video playback.
±0.3 °C below 250 °C and ±0.5 °C above, with ±0.1 °C repeatability.
Order or ask for a quotation
The price shown is for the basic model; call us for the others. Add it to your cart, or call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.