The HSCo HSC-C-RT21FLR is a floor-standing, refrigerated high-speed centrifuge: up to 21,000 rpm (50,400 × g) and up to 6 × 500 ml, with the chamber held anywhere from −20 to +40 °C within ±1 °C by a French Tecumseh compressor with R404a refrigerant. The speed holds within ±10 rpm and the timer runs from 1 second to 99 h 59 min 59 s. A front touch screen runs it, with up to 100 stored programs, and it recognises the rotor fitted, locks the lid and raises an alarm on over-speed, over-temperature or imbalance. Rotors range from 36 micro tubes to 6 × 500 ml bottles, and two continuous-flow rotors process 1,000 or 3,000 ml at 200 to 800 ml a minute.
Why labs choose the RT21FLR
- Up to 21,000 rpm / 50,400 × g.
- Up to 6 × 500 ml, plus continuous-flow rotors.
- Keeps samples cold: −20 to +40 °C, ±1 °C.
- Touch screen and 100 programs, with multi-step runs.
- Safe: rotor recognition, lid lock, alarms; run and fault records by USB.
Specifications
| Model | HSC-C-RT21FLR (RT21FLR) |
|---|---|
| Type | Floor-standing, refrigerated, high speed |
| Maximum speed / RCF | 21,000 rpm / 50,400 × g |
| Maximum capacity | 6 × 500 ml |
| Speed accuracy | ±10 rpm |
| Timer | 1 s – 99 h 59 min 59 s |
| Temperature | −20 to +40 °C, accuracy ±1 °C |
| Refrigeration | French Tecumseh compressor, R404a |
| Control | Microcomputer; front LCD touch screen; up to 100 user programs, multi-step programs; 10 acceleration and 11 deceleration levels, free coast-down |
| Safety | Electronic lid lock (self-locking), automatic rotor recognition; alarms for over-speed, over-temperature and imbalance |
| Records | Run data and fault record stored; read and print through USB |
| Motor | AC variable-frequency motor, high torque |
| Bottles | Clear PC bottles, can be sterilised at high temperature |
| Noise | Under 65 dB(A) |
| Power | AC 220 V, 50 – 60 Hz; 5 kW |
| Size | 900 × 760 × 1,005 mm; packed 1,020 × 880 × 1,105 mm |
| Net weight | 350 kg (without rotor) |
| Warranty | 1 year |
| Rotor shown | Capacity | Max speed | Max RCF |
|---|---|---|---|
| No. 1 | 36 × 1.5 / 2.2 ml (adaptors 0.2, 0.5 ml) | 21,000 rpm | 50,400 × g |
| No. 2 | 12 × 20 ml (adaptors 5, 10 ml) | 16,500 rpm | 31,100 × g |
| No. 3 | 18 × 10 ml (adaptors 1.5, 5 ml) | 21,000 rpm | 50,400 × g |
| No. 4 | 8 × 50 ml (adaptors 10, 20 ml) | 18,000 rpm | 35,047 × g |
| No. 10 | 6 × 500 ml (adaptors 50, 100, 250 ml) | 9,000 rpm | 14,400 × g |
| No. 13 | 6 × 250 ml (adaptors 50, 100 ml) | 12,000 rpm | 22,470 × g |
| No. 25 | 12 × 15 ml | 16,000 rpm | 30,194 × g |
| No. 23 continuous | 1,000 ml; flow 200 – 600 ml/min; aluminium alloy | 16,000 rpm | 28,100 × g |
| No. 24 continuous | 3,000 ml; flow 200 – 800 ml/min; aluminium alloy | 10,000 rpm | 14,800 × g |
Other rotors supplied: angle rotors 16 × 10 ml and 16 × 5 ml (21,000 rpm, 50,400 × g), 6 × 50 ml (20,000 rpm), 6 × 70 ml (15,000 rpm), 8 × 100 ml and 32 × 15 ml (14,000 rpm), 6 × 300 ml (11,000 rpm); swing-out rotors 4 × 50 / 4 × 85 ml (8,000 rpm), 4 × 750 ml, 8 × 50 / 32 × 15 ml and 96 × 10 / 72 × 15 / 20 × 50 ml (5,000 rpm), and microplates 2 × 2 × 96 (4,000 rpm).
Which centrifuge?
For 22,000 rpm and 6 × 600 ml, see the HSC-C-RT22FLR; with an LCD and keypad at 21,000 rpm, the HSC-C-RK21FLR; for 25,000 rpm, the HSC-C-RT25FLR. Browse all centrifuges.
Where it is used
High-speed, high-volume separations that must stay cold, in research, clinical and industrial labs.
Questions buyers ask
Up to 21,000 rpm (50,400 × g) with the 36-place micro-tube and 18 × 10 ml rotors; see the rotor table for the others.
Six 500 ml bottles, or up to 3,000 ml in the continuous-flow rotor.
You can set the chamber from −20 to +40 °C; it holds the setting within ±1 °C.
Order or ask for a quotation
Tell us your tubes and volumes so we can suggest the rotor. Add it to your cart, or call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.