Weighing & Business

Scale accuracy class: what Class I, II, III and IV mean on your scale

HSCo SSBP stainless steel table-top scale with a pole display

A scale accuracy class sets the error limits a non-automatic weighing scale must meet when it is verified and stamped, counted in its verification scale interval e. The Legal Metrology (General) Rules, 2011 set four classes: I (special), II (high), III (medium) and IV (ordinary) [1]. A Class III scale with e = 5 g has a verification limit of ±2.5 g in its lowest load band [1].

On 19 October 2026, the Press Information Bureau announced that India would host the 61st meeting of the International Committee of Legal Metrology (CIML) for the first time, organised by the Department of Consumer Affairs with the International Organization of Legal Metrology (OIML) [2]. It said the agenda would include international recommendations and the OIML Certification System [2]. The release gave the meeting dates as 26 to 28 October 2026, in New Delhi [2]. In India, the classes on a scale come from the 2011 Rules [1].

What does scale accuracy class mean?

The class sets the error limit, written in units of e. The Rules sort non-automatic weighing instruments by two numbers: the verification scale interval e, and n, the number of those intervals in the maximum capacity (n = Max ÷ e) [1]. The errors allowed are of the same order as e [1].

Classe allowedn, from and toMin, lower limit
I, special0.001 g or more50,000 to no upper limit; fewer if d is under 0.1 mg100 e
II, high0.001 g to 0.05 g100 to 1,00,00020 e
II, high0.1 g or more5,000 to 1,00,00050 e
III, medium0.1 g to 2 g100 to 10,00020 e
III, medium5 g or more500 to 10,00020 e
IV, ordinary5 g or more100 to 1,00010 e
Bar chart of the maximum number of verification intervals for Class II, III and IV
Maximum number of verification intervals for Classes II, III and IV, from Table 17 of the Legal Metrology (General) Rules, 2011.

How much error does a Class III scale allow?

The limit rises with the load, in steps of 0.5 e. At verification and re-verification, the tested error of a Class III scale may be at most ±0.5 e from Min up to 500 e, ±1 e above 500 e up to 2,000 e, and ±1.5 e above 2,000 e up to 10,000 e [1]. At an in-service inspection, the limits are twice these values [1].

Take a single-interval 30 kg shop scale marked Class III, e = 5 g and Min = 100 g. Its n is 30,000 g ÷ 5 g = 6,000, inside the Class III ceiling of 10,000, and its Min equals the 20 × 5 g = 100 g lower limit in Table 17 [1].

Error limit = 0.5 e, 1 e or 1.5 e by load band; at an in-service inspection, twice that

Load on the scaleLoad in eVerification and re-verification limitIn-service inspection limit
100 g to 2.5 kg20 e to 500 e±2.5 g±5 g
Over 2.5 kg to 10 kgOver 500 e to 2,000 e±5 g±10 g
Over 10 kg to 30 kgOver 2,000 e to 6,000 e±7.5 g±15 g
Bar chart of tested error limits by load for a 30 kg Class III scale with e = 5 g
Worked example: tested error limits on a 30 kg Class III scale with e = 5 g, at verification or re-verification and at an in-service inspection.

On this scale, the tested error on a 25 kg sack may be at most 7.5 g at verification and 15 g at an in-service inspection. A 200 g packet is 40 e, so its limits are 2.5 g and 5 g.

Can I weigh 50 g on a 30 kg scale?

The Rules list a minimum capacity, Min, among the markings on the non-automatic weighing instruments they cover, to mark the load below which the instrument should not be used [1]. The 30 kg example is marked Min = 100 g, so 50 g of cardamom belongs on a scale with a marked Min of 50 g or less and a weighing range that includes 50 g. By Table 17, Min can be no lower than 2 g on a Class III scale with e = 0.1 g, or 0.2 g on a Class II balance with e = 0.01 g [1].

Gloved hands placing a powder sample on a precision balance in a QC lab
Illustration. A QC technician places a powder sample on a precision balance with a glass draft shield.

Which HSCo scale fits your accuracy need?

Pick the capacity first, then read the class, Min and e marked on the scale before you buy.

HSCo LAB300 precision laboratory balance with a glass draft shield and round pan
The LAB300 precision balance, 300 g capacity with 0.001 g readability.

For packing and dispatch counters, see our warehouse and e-commerce scales, and for balances, our laboratory scales. Tell us what you weigh and the smallest load you need: call +91-7045922250 or write to hsc@hindustanscale.com.

Frequently asked questions

What is the difference between Class II and Class III scales?

A Class II scale may divide its capacity into up to 1,00,000 verification intervals, while a Class III scale may use up to 10,000, under the Legal Metrology (General) Rules, 2011 [1]. Class II allows e from 0.001 g, so it covers balances that weigh in milligrams. Class III starts at e = 0.1 g.

What is e on a weighing scale?

On a weighing scale, e is the verification scale interval. The Legal Metrology (General) Rules, 2011 require e to be 1, 2 or 5 times a power of ten and require it marked on the scale as e = [1]. The error limits are counted in e, so a Class III scale with e = 5 g may err by at most 2.5 g from Min up to 500 e at verification [1].

What does Min mean on a weighing scale?

Min is the minimum capacity marked on a weighing scale. The Legal Metrology (General) Rules, 2011 say Min marks the load below which the scale should not be used, and Table 17 sets 20 e as the lower limit for Min on a Class III scale [1]. For a Class III scale with e = 5 g, that lower limit works out to 100 g. Check the Min marked on the scale before you weigh small lots.

Sources

  1. Ministry of Consumer Affairs, Food and Public Distribution (copy hosted by the Legal Metrology Department, Meghalaya), “The Legal Metrology (General) Rules, 2011 (Gazette of India text)” (megweights.gov.in, 7 February 2011). G.S.R. 71(E) dated 7 February 2011; Seventh Schedule, non-automatic weighing instruments, Tables 15 to 20 and markings
  2. Press Information Bureau, “India to Host 61st Meeting of International Committee of Legal Metrology for the First Time in New Delhi from 26–28 October 2026” (pib.gov.in, 19 October 2026). Ministry of Consumer Affairs, Food and Public Distribution
  3. Hindustan Scale Company, “SSBP Table Top Scale with Pole Display – 10, 30, 50 kg, Stainless” (hindustanscale.com). product page
  4. Hindustan Scale Company, “PLCHQS Electronic Platform Scale – 50 to 300 kg, Chequered Plate, Double Display” (hindustanscale.com). product page
  5. Hindustan Scale Company, “LAB300 Precision Laboratory Balance – 300 g × 0.001 g” (hindustanscale.com). product page
author-avatar

About Haider Kantawala

Haider Kantawala, Partner at Hindustan Scale Company, brings a blend of technical expertise and strategic leadership to the company’s product innovation, corporate communications, and digital presence. With prior experience as a Solution Architect at TCS and a formal background in Marketing, he plays a pivotal role in guiding HSCo’s direction in both product development and customer education. Haider regularly authors insightful blog posts and shares industry perspectives, reinforcing HSCo’s position as a thought leader in precision weighing solutions.

Leave a Reply

Your email address will not be published. Required fields are marked *