The HSC high volume air sampler (HVAS) draws a large, steady volume of ambient air through a filter so that suspended particulate matter can be collected, weighed and analysed. It is built for SPM and respirable dust sampling, including PM10 and PM2.5 work, in air-quality monitoring, industrial emission studies and pollution-control research.
How it works
A high-efficiency blower pulls air through an 8 × 10 inch glass-fibre or paper filter at a controlled flow rate for a timed run. Weighing the filter before and after the run, and dividing the dust collected by the volume of air sampled, gives the particulate concentration.
Specifications
| Type | High volume air sampler; SPM / RPM / PM10 / PM2.5 compatible |
|---|---|
| Air flow rate | Up to 1.0 – 1.5 m³/min, adjustable |
| Flow measurement | Digital flow meter or orifice manometer |
| Flow control | Manual or automatic constant-flow controller |
| Filter holder | 8″ × 10″ glass-fibre or paper filters |
| Filter efficiency | ≥ 99% for 0.3 µm particles, with suitable filter media |
| Timer | Programmable, up to 24 hours continuous operation |
| Motor | Brushless, high-speed, continuous duty |
| Noise | Below 70 dB at 1 m |
| Power | 230 V ± 10%, 50 Hz, single-phase AC |
| Construction | Powder-coated mild steel or stainless steel, as per model; weather-resistant, portable cabinet with lockable door |
| Accessories | Filter papers, flow calibrator, sampling stand, dust collection tray |
| Warranty | 1 year |
Where the table gives two options, they depend on the model; tell us which you need.
Where it is used
Ambient air monitoring stations, industrial emission and workplace-dust studies, environmental research and pollution-control laboratories.
Questions buyers ask
It collects suspended particulate matter from a known volume of air on a filter; weighing the filter gives the dust concentration.
Yes. It is compatible with SPM, RPM, PM10 and PM2.5 sampling.
Up to 24 hours continuously, set on the programmable timer.
Yes. The cabinet is weather resistant, with a lockable door.
Filter papers, a flow calibrator, a sampling stand and a dust collection tray.
Ask for a quotation
Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com with the pollutants you sample, the construction (mild steel or stainless) and the flow control you prefer. Hindustan Scale Company, Mumbai, since 1955.