HSC-I-CFMF 1600 °C ceramic fibre muffle furnace, white cabinet with control panel
1600 °C Ceramic Fibre Muffle Furnace HSC-I-CFMF – 2 to 36 L Price range: ₹49,500.00 through ₹175,000.00 (ex. GST) (₹58,410.00 – ₹206,500.00 incl. GST)
Back to products

Laminar Flow Cabinet HSC-I-NLFC – Vertical, Class 100, HEPA, One or Two Persons

Price on Request

★★★★★4.8from 1,363 Google reviews of Hindustan Scale CompanyRead reviews ›

Vertical laminar flow cabinet HSC-I-NLFC: class 100 clean air, HEPA ≥ 99.995% at 0.3 µm, one-person or two-person widths, used from one side or both, SUS304 work area, tempered-glass door, UV and fluorescent lamps, LCD controller with adjustable air speed, 2 sockets. 1-year warranty.

Price on Request

Ask for a quotation

Or call +91-7045922250 or use the WhatsApp button.

Description

The HSCo HSC-I-NLFC laminar flow cabinet gives a clean, particle-free work area by blowing HEPA-filtered air vertically down over the work surface. It reaches cleanliness class 100, with a HEPA filter that stops at least 99.995% of 0.3 µm particles. It comes in one-person and two-person widths, for use from one side or both. It has a SUS304 stainless-steel work area, a tempered-glass front, UV and fluorescent lamps, and an LCD controller with adjustable air speed. It is used for microbiology, tissue culture, pharmaceutical compounding and electronics assembly.

Why labs choose it

  • Vertical laminar flow, cleanliness class 100.
  • HEPA filtration: ≥ 99.995% at 0.3 µm, with a pre-filter.
  • One or two operators, working from one side or both.
  • UV sterilisation lamp and fluorescent lighting, one-key on/off.
  • LCD colour controller with multi-level air speed and filter and lamp replacement reminders.
  • Quiet and steady: ≤ 62 dB, ≤ 3 µm vibration.

Specifications

SpecificationOne-person (1D / 1S)Two-person (2D / 2S)
Inner work area (W × D × H)920 × 690 × 650 mm1,320 × 690 × 650 mm
Outer size (W × D × H)1,060 × 763 × 1,834 mm1,460 × 763 × 1,834 mm
HEPA filter900 × 640 × 50 mm1,300 × 640 × 50 mm
Pre-filter464 × 360 × 5 mm712 × 360 × 5 mm
Fluorescent / UV lamp16 W / 20 W24 W / 30 W
Fan180 W × 1180 W × 2
Rated power / current240 W / 1.8 A440 W / 3.6 A
Net weight160 – 165 kg200 – 205 kg
ModelsHSC-I-NLFC-1D, 1S, 2D, 2S (II and III versions); 1 = one person, 2 = two persons; D = used from one side, S = used from both sides
AirflowVertical; 0.2 – 0.6 m/s, multi-level adjustable
CleanlinessClass 100; ≥ 99.995% at 0.3 µm; ≤ 0.5 colonies per 90 mm dish
Noise / vibration≤ 62 dB / ≤ 3 µm
Lighting≥ 500 lx
Work surface load50 kg
ConstructionSUS304 stainless inner; powder-coated cold-rolled steel outer; tempered-glass door
ControllerLCD colour screen; filter and UV-lamp replacement reminders; one-key light / UV
Sockets2 built-in, up to 800 W each
Power220 V AC, 50/60 Hz
Warranty1 year

Which cabinet?

A laminar flow cabinet protects the sample. To protect the operator as well when working with pathogens, choose the Class II A2 biosafety cabinet. Browse all laboratory furniture.

Where it is used

Microbiology and tissue-culture labs, pharmaceutical compounding and QC, hospitals, research institutes, and electronics assembly.

Questions buyers ask

D models are used from one side; S models from both sides (as listed in the model table).

Class 100: the HEPA filter stops at least 99.995% of 0.3 µm particles.

No. A laminar flow cabinet protects the sample. For work with pathogens, use a biosafety cabinet.

Yes, for sterilising the work area, with a one-key switch and a replacement reminder.

Ask for a quotation

Tell us how many operators and whether they work from one side or both. Call or WhatsApp +91-7045922250 or email hsc@hindustanscale.com. Hindustan Scale Company, Mumbai, since 1955.